piMAGGYRO
Non-deployable tri-axial digital CubeSat magnetometer and gyroscope with telemetry engine for in-situ magnetic field and tumbling rate measurement.
Technical specifications
- Type
- Digital CubeSat tri-axial magnetometer and gyroscope
- Magnetic field range
- +/- 300,000 nT per axis (0-519,615 nT total magnetic field maximum range)
- Magnetic field resolution
- 6 nT resolution, 35 nTrms noise (total magnetic field)
- Angular rate range
- +/- 250 deg/s per axis, 1 deg/s resolution
- TRL
- 9 (flight-proven)
- Output interface
- UART serial output, 115200 bps-8-n-1 LVCMOS format
- Power requirements
- +3.3V, 14mA, 50mW
- Update rate
- 10 Hz
- Alarms
- OVERFLUX (80,000 nT total field exceeded), OVERRATE (100 deg/s exceeded), ERROR signal
- Housing
- Non-magnetic Al-6061-T6
- Connector
- 2x5 pin 2 mm pitch header
- Operating temperature
- -40 C to +85 C
- Power supply input range
- 2.8 to 3.6 V
- Dimensions
- 53x32x(+14,-2) mm
- Mass
- 33 g (excluding mounting screws)
- Country of origin
- Czech Republic
About
The piMAGGYRO is a Space-Friendly non-deployable tri-axial digital CubeSat magnetometer and gyroscope with a telemetry engine, designed to provide in-situ magnetic field measurements in orbit together with angular rate sensing. Bx, By, Bz, Bt magnetic field components and angular rate components are provided at a 10 Hz update rate, along with unit temperature, input voltage, and uptime sampling in 100 ms steps via internal timestamping. The unit is especially suitable for geomagnetic field measurement and safety precautions for free-flying satellites, docking systems, large booms, solar sails, solar wing panels, or active ADCS/propulsion-equipped satellites with no deployables needed. The unit can activate OVERFLUX, OVERRATE, and ERROR alarm signals over GPIO within 25 ms reaction time to inform the upper-level system of artificially disturbed geomagnetic fields, dangerous tumbling rates, or unexpected space events. No commands or settings are required to get data out.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.