HARDWARE / PRODUCT

Synthesis System of IR Images

Glavkosmos
Synthesis System of IR Images

Operation princicple is based on the use of two independent high-speed channels of the tested product's surface illumination - the object channel (CO) and the background channel (CF).

Technical specifications

Working spectral range
2,5 - 4,6 mkm
Diameter of a point object in the image plane for object channel
< 30 mkm
The concentration ratio of energy in the spot scattering for object channel
> 0,75 ± 0,07
Irradiation in image plane for object channel
10-9 - 10-6 w/cm2
Irradiation in image plane for background noise channel
10-9 - 10-7 w/cm2
Scanning device positioning error
> 2 mkm