HARDWARE / PRODUCT

Mechanical Unit of Antenna Pointing System. Type 2

Glavkosmos
Mechanical Unit of Antenna Pointing System. Type 2

Two-degree-of-freedom electromechanical drive for antenna pointing.

Technical specifications

Rotation angle for each axis, °
± 25
Slew rate, °/min
0.009- 7.1
Measurement error of the rotation angle for each axis, arcsec, not exceeding
90
Developed torque for each axis, N·m, not less than
30
Load inertia moment, kg·m2, not exceeding
3
Self-braking torque in a de-energized state of the electric motors for each axis, N·m, not less than
4
Operating temperature range, °С
-50 to +50
Operational life defined by hours, not less than
44000
Active lifetime, years
10
Overall guaranteed lifetime, years
14