Force Sensor Vt 114
Version: strain gage sensor, consisting of a cylindrical type elastic element, strain gages connected in two bridge circuits, a casing, a power input unit and a plug. Type of protection - “Intrinsically safe electrical circuit” - is provided by an intermediate converter.
Technical specifications
- Range of measurements, kN
- ±130
- The basic error,%, not more
- 1
- Rated output signal, mV / V
- 1,5+0,22-0,15
- Supply voltage
- 9±1,8; 12±2,4
- Weight, kg, not more
- 4
About
Version: strain gage sensor, consisting of a cylindrical type elastic element, strain gages connected in two bridge circuits, a casing, a power input unit and a plug. Type of protection – “Intrinsically safe electrical circuit” – is provided by an intermediate converter.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.